2014 60,000CFM Dust Collection System





Technical Specifications:

· air volume : 60000 cfm

· Filtering area: 7971 sq.ft.

· air-to-cloth ratio : 7 to 1

· compressed air requirement : 45 cfm at 90 psig and – 40° C degree dew point

Walk in service plenum :

· Fabricated of mild steel 11 ga.

· access door with platform

· heat detector, model Chubb CF200-EWT

· internal deluge system with ( 4 ) sprinkler heads piped to outside the unit Ø 1 ½” NPT

· clean air outlet with fire damper ( fusible link )

Pulsed-air cleaning system :

· ( 3 ) compressed air headers c/w :

· inlet pipe Ø 2” NPT with ball valve

· pressure gauge

· drain Ø ¾” with ball valve

· outlet pipes Ø 1 ½” and 2″ NPT

· ( 10 ) Goyen double-diaphragm valves Ø 1½"

· ( 14 ) Goyen double-diaphragm valves Ø 2”

· ( 3 ) Enclosure Goyen solenoid valves RCA3-8V-8000 AC

· ( 10 ) shut-off valves Ø 1½"

· ( 14 ) shut-off valves Ø 2"

· ( 10 ) blow pipes Ø1½" assembly with quick-couplings

· ( 14 ) blow pipes Ø 2" assembly with quick-couplings

· Dwyer Controller Nema 4

· timer controller

· pressure module


Filtering section :

· fabricated of mild steel 11 ga.

· ( 408 ) polyester filters bags Ø 160 x 3700 mm

· polyester felt 14.7-17.3 oz/yd2

· air permeability 20-40 cfm

· finish : heat set, glazed one side

· snap band fixations

· (408 ) filter bag’s galvanized steel cages with integrated venturi

· ( 6 ) explosion vents doors with Brixon latches model 3H, NFPA-68 norms


Cyclonic separator section :

· fabricated of mild steel 11 ga.

· twin-body cylindrical shell with vortex breaker

· tangential air dust inlet



Conical hopper section :

· fabricated of mild steel 11 ga.

· vortex breaker c/w :access door

· plug-up detector

· Structural steel support frame

· 6’foot of clearance under rotary airlock

Access platform :

· to the door access at the service plenum

· galvanised steel grating

· handrails


Back flow preventers

· One (1) Back flow preventer c/w explosion panel on the 48”Ø pipe on the intake side before each of the bag-houses. This is to prevent any possibility of explosions and debris re-entering the building thru the ducting.


Hi-Speed Abort Gates

Four (4) Clarke’s CP-45 Hi-Speed Abort Gates including the following:

· Limit switch indicator for aborted position.

· Hi-Speed abort gate actuates in approximately 500 milliseconds with loaded torsion spring and gravity assist.

· Heavy duty welded construction.

· Magna-Latch Actuator requiring 110 Volt AC input power source.

· Powered Reset Function.

· Inlet and outlet transitions flanged and co-flanged for 48” Duct.

· Weather hood.

· Gray primer with a finish coat of safety yellow enamel.


Radial Blade Fan

· Two (2) model 95 RB, arrangement 60,000cfm @ 15.5” s.p. 769 rpm, BHP 248.83

· Flanged inlet and outlet- standard on all sizes

· Shafting- high quality, close tolerances, turned ground and polished.

· Precision balancing- all RB wheels are statically and dynamically balanced before final assembly.

· Heavy-duty spherical roller bearings- selected for long life through applicable speed range

· Properly sizes sheaves and belts and guard for the new design.

· 300 hp 575 volt motor


Rotary Airlock,

· Two(2)model: CI-22 x 22

· cast iron housing

· end plates with fabricated 8-vane open end mild steel rotor

· outboard bearings

· ACS packing shaft seal assembly

· adjustable/replaceable hardened steel rotor tips, bevelled and blade ends to be hard faced

· chain and sprockets drive assembly

· safety guard

· Eurodrive gearmotor 5 HP, 575/3/60, TEFC

· zero speed switches XSAV11801

Item #1 – Basic System


· Two (2) Pyro-Guard CXL-8 control console with three (3) I/O cards capable of monitoring six (6) zones and three (3) Termination Module cards. Sensor and valve auto testing, with the ability to count sparks, activate deluge valves, abort gates and external warning devices, with battery back-up.

· Shop testing, crating, and handling.

· Two (2) Operational Maintenance Manuals.

· One (1) Installation Guide.

· One (1) Set of Installation Tools.

· One (1) Constant Voltage Power Conditioner.